Surge protection device Heschen PV
- Maximum continuous operating voltage: 1300 VDC
- Voltage protection level: 4.0 kV
- Rated working voltage Un: 1000 VDC
- Maximum discharge current: 40 kA
- Response time: <25 ns, IP 20, 50/60 Hz



1. U-type structure, limit pressure type combination. Common differential mode protection mode.
2. Built-in overheat and overcurrent protection mechanism.
3. Built-in overheat and overcurrent protection mechanism.
4. Built-in overheat and overcurrent protection mechanism.
5. Local fault indication, white for normal operation, red after tripping.

6. Use standard 35mm rail installation and connect 6 to 35mm3 multi-core copper cables.
7. The earthing cable should be a two-coloured cable with a length of more than 16 mm and a length of not more than 500 mm.
8. To prevent the failure of the surge protector after the grid safety impact, each pole must be connected in series with a front surge protector LYSCB backup protector.
Surge protection device Heschen PV
Spain
Copy the promo code and paste it at checkout to find out your discount amount
Pay with Visa/MasterCard (LiqPay), Apple Pay, PrivatPay Google Pay, PayPal, payment via IBAN. Request an invoice
Return the product within 14 days. more details about the return conditions
We do everything we can to protect your security and privacy. Our payment security system encrypts your data during transmission. We do not provide your credit card details to third parties and do not sell your information to third parties. Free shipping applies only to small-format goods, more about shipping and rates.
- Maximum continuous operating voltage: 1300 VDC
- Voltage protection level: 4.0 kV
- Rated working voltage Un: 1000 VDC
- Maximum discharge current: 40 kA
- Response time: <25 ns, IP 20, 50/60 Hz



1. U-type structure, limit pressure type combination. Common differential mode protection mode.
2. Built-in overheat and overcurrent protection mechanism.
3. Built-in overheat and overcurrent protection mechanism.
4. Built-in overheat and overcurrent protection mechanism.
5. Local fault indication, white for normal operation, red after tripping.

6. Use standard 35mm rail installation and connect 6 to 35mm3 multi-core copper cables.
7. The earthing cable should be a two-coloured cable with a length of more than 16 mm and a length of not more than 500 mm.
8. To prevent the failure of the surge protector after the grid safety impact, each pole must be connected in series with a front surge protector LYSCB backup protector.
Surge Protector, 35mm DIN Rail Mount, Solar Systems, Protection Device, DC Circuits, Electrical Safety, PV Systems